Our KPC-HV1875 6KV high voltage 1500kw KANPOR KANGMINGSI diesel generating set offers a range of automated features, ease-of-operation, fuel efficiency, and added convenience to ensure reliable and efficient power generation. Besides, it includes engine control and generator protection for optimal performance and reliability.
DIESEL GENERATOR | |||||||
---|---|---|---|---|---|---|---|
Powered by KANPOR KANGMINGSI Engine & LeroySomer/Stamford/Kanpor Alernator | |||||||
STANDARD SPECIFICATION | |||||||
Three phase four wire,output voltage 0.6KV ,50HZ,between 0.8 lagging,protection capability according with the standard of NAME1 and IP23. | |||||||
General Features: | |||||||
ΔComposed of KANPOR KANGMINGSI diesel engine and Stamford alternator | |||||||
ΔOil and fuel filter fitted,water separator | |||||||
ΔLube-oil drain valve fitted | |||||||
ΔElectric Starter Charge motor 24 VD.C | |||||||
ΔWater-cooled | |||||||
Δ baseskid fuel tank | |||||||
ΔAuto start | |||||||
ΔOptional soundproof and weatherproof canopy | |||||||
Δ 3 pole MCCB Delixi breaker/Optional ABB | |||||||
Δ Operation & Maintenance manual | |||||||
ΔSpecial Integrated Steel Base tank and sprayed overall in gloss enamel paint | |||||||
Voltage Regulation | |||||||
Voltage regulation maintanined within ±0.5% | |||||||
Between 0.8 and 1.0 lagging and unity | |||||||
From no load to full load | |||||||
At speed droop variation upto 4.5% | |||||||
Frequency Adjustable Ratio | |||||||
Change load from 0-100%,within 1.0%( electric speed regulator),within 4.5%( mechanical speed regulator) | |||||||
Frequency Undulation | |||||||
load from 0-100%,frequency undulation within 0.25% | |||||||
No load wire volts max undulation ration\ within 1.8% | |||||||
Three Phrase balanced load in the order of 5% | |||||||
Effect factor of Telecom | |||||||
TIF better than 50 | |||||||
THF to IEC60034 Part 40 better than 2% | |||||||
50HZ, 1500RPM, 3-PHASE,0.6KV | |||||||
Gensets model | Power output(KVA) | Power output (KW) | KANPOR KANGMINGSI Engine Model | Stamford Alternator | |||
Standby Power | Prime Power | Standby Power | Prime Power | ||||
KPC-HV1875 | 1875 | 1688 | 1500 | 1350 | KTA50-G15 | P80-HVSI804R | |
Note: | |||||||
(1) Available ODM/OEM | |||||||
(2) PRP:Prime Power-Continuous duty operation,under variable load 24/24-h-10% overload permissible 1 hour/12hours. | |||||||
(3) Rating Definitions (Operation at Altitude ≤1000m, Ambient temperature ≤ 40℃)Continuous Power.These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. | |||||||
Engine & Alternator | |||||||
ENGINE--Industrial 4 stroke cooled diesel engine complete with air,fuel and oil filters,electric starting and charging equipment,engine protection against low water level. | |||||||
ALTERNATOR--Brushless,self exciting,self regulation,sreen protected,drip proof rated in accordance with IEC60034.Voltage regulation maintainted within ±0.5% from no load to full load.between 0.8 lagging and unity.All standard voltages available. | |||||||
COOLING--Radiator and colling fan complete with protection guards,designed to cool engine at specified output in air temperatures upto 45 ℃,radiators suitable for higher temperatures are available.Low water level protection fitted as standard. | |||||||
ELECTRICAL SYSTEM--24V upto.Axial type starter motor,battery charging alternator,high capacity lead acid battery,and battery tray mounted on the generator base frame,and heavy duty interconnecting cable with terminations. | |||||||
EXHAUST SYSTEM--Heavy duty industrial exhauset silencer with flexible piping. | |||||||
Technical Data Sheet | |||||||
Generating sets model: | |||||||
6000V,50Hz,1500 rpm | Genset Option Features | ||||||
Engine Model: | KANPOR KANGMINGSI KTA50-G15 |
ΔLow fuel level alarm shutdown | |||||
Type | 16-V cylinder,4 cycle diesel | ΔAutomatic Fuel Filling System | |||||
Aspiration | Turbocharged and Aftercooled | ΔEngine oil feeding and drain pump | |||||
Bore/Stroke mm | 159X159 | ΔAuto Transfter Switch( ATS) | |||||
Compress the ratio | 13.9:1 | ΔParallel control panels | |||||
Cooling system | Water-cooled | ΔCircuit Breaker MCCB & ACB | |||||
100% Load Fuel Consumption L/H | 346 | ΔRemote Control Panel | |||||
Engine Speed/Frequency RPM/Hz | 1500/50HZ | Δweatherproof/soundproof Canopy | |||||
Rated Output kw/Bhp | 1656/2208 | ΔTrailer type Gensets | |||||
Exhaust air flow ( m3/min) | 198.4 | QUALITY STANDARDS | |||||
Coolant Capacity L | 422 | ISO9001:2000,ISO14000,ISO3046 | |||||
Starting System | Electric 24 volt DC | ISO8528 BS4999 | |||||
Displacement L | 50.3 | BS5514,AS1359,ICE34 | |||||
Lubricant system Capacity L | 204 | CE Compliance | |||||
Battery Volatge / Capacity | 24VDC | Gensets Dimensions & Weight | |||||
Governing Type | Electrical (GAC governor) | Open type:L*W*H,mm | |||||
Exhaust Gas Temperature ℃ | 529 | 5250*2110*2550MM / 10600kgs | |||||
Exhaust Gas flow m3/min | 272.7 | Enclosure type:L*W*H,mm | |||||
Noise level dBA@7m | ≤85dBA(canopy type) | 40HQ container type/12192*2438*2896MM 16200KGS | |||||
Alternator Technical data | |||||||
STAMFORD | |||||||
Δ Bruxhless,self exciting | Exciter | Brushless | |||||
Δclass "H" insulation | Cooling Fan | Cast alloy aluminum | |||||
Δ Standard degree of protection is IP23 | Bearing | Single,double shielded | |||||
Δself regulating | Windings | 100% copper | |||||
Δ With fan cooling | Connection Type | Reconnectable | |||||
Δ Resist Humid grease | Insulation Type | Class H | |||||
ΔAC excitation,roating rectification tube | Pitch | 2/3 | |||||
Δ Stator grease insulation covered | Amortisseur Winding | Full | |||||
ΔRotator and exciation high polymer,Resist the corruption of oil and acid | Voltage Regulator | AVR R448 | |||||
Voltage Regulator NL-FL | ±0.5% | ||||||
Δ Rotator ballance is in accordance with BS5625 standard 12.5 | Underspeed Protection | Standard | |||||
Overexcitation Protection | IP23 | ||||||
Δ High-quality lubrication sealed long-time bearing | TIF (1960 Weightings) | <50 | |||||
Δ Rotator sillicon steel close tight | Exciation System | AREP | |||||
Control Panel- ComAp AMF20 | |||||||
The base mounted control panel in a vibration isolated sheet steel enclosure.The control panel is equipped as follows: | |||||||
a)Instruments:Analogue Volmeter,Hours Run Meter.Water pressure Meter. | |||||||
b) Controls:Emergency Stop Pushbutton,Volmeter Phase Selector Switch. | |||||||
c) Control module:Standard collocation ComAp AMF20 | |||||||
Main Features: | |||||||
Δ Automatic mains failureΔ Engine control,Generator protectionΔ Built in alarms and warningsΔ Remote Start operation availableΔ Daily / weekly / monthly exerciserΔ Weekly operation schedule programsΔ Fuel pump controlΔ Mains simulationΔ Block heater controlΔ Field adjustable parametersΔ Free MS-Windows Remote monitoringΔ LED displaysΔ Configurable analogue inputsΔ I/O expansion capabilityΔ I/O expansion capability | |||||||
ComAp AMF20 / AMF25 / IG NTC (Synch.using) | |||||||
Sound Attenuated Enclosure/Option | |||||||
Robust Corrosion Resustant Construction | |||||||
Δ Black finish stainless stell lock and hinges | |||||||
Δbody made from steelcomponents treated with polyester powder coating | |||||||
Excellent Access for Maintenance | |||||||
Δtwo large doors on each side | |||||||
Δradiator fill access plate | |||||||
Δlube oil and cooling water drains pipes to exterior of the enclosure | |||||||
Security and Safety | |||||||
Δcontrol panel viewing window in a lockable access door | |||||||
Δemergency stop push buttom (red)mounted on enclosure interior | |||||||
Δcooling fan and battery charging alternator fully guarded | |||||||
Δexhaust silencing system totally enclosed for operator safely |
Automated Features:
The automatic mains failure feature ensures that the generator kicks in seamlessly during power outages.
It includes engine control and generator protection for optimal performance and reliability.
Built-in alarms and warnings alert the user of issues or potential problems.
Ease of Operation:
Remote start operation is available for added convenience.
The daily, weekly, and monthly exerciser options ensure the generator is well-maintained and prepared for use when needed.
The weekly operation schedule programs allow for customized scheduling based on specific needs.
Fuel Efficiency:
Fuel pump control ensures optimal fuel usage and efficiency.
Mains simulation further boosts fuel economy by reducing unnecessary generator usage.
Added Convenience:
The block heater control helps to maintain optimal operating temperatures in cold weather conditions.
Controller Brand | Control Panel |
---|---|
Deepsea , ComAp, Smartgen | English interface,LED screen and touch buttons. |
Control, monitor and protect the Generator Set including | |
*High water temperature *Low oil pressure *Over and under speed *Over current *Under/Over generator voltage *Start and stop failure *Low and high battery voltage *Charge fail *Emergency stop |
1.) Closed water-cooled diesel engine
2.) AC brush less generator
3.) Steel CNC bending public chassis
4.) 40 °C ambient temperature full protection tank radiator
5.) Fully enclosed Acid battery and copper battery connection cable
6.) Battery-negative circuit breaker
7.) KANPOR molded case main breaker
8.) 24V battery float charger
9.) Composite high-performance bowl-type shock absorber
10.) Industrial muffler
FREE UPDATE TO:
--AC brush less generator with the best AVR
--50 °C ambient temperature full protection tank radiator
--maintenance-free battery
--Delixi / CHINT / ABB /Schneider main breaker.
--1mm wire to 1.5mm wire
--Thicker 1mm than 90% of other suppliers on frame/tank/canopy.